Wheelchair Accessibility Analysis

    Room Schedule: SO-100 - Ruimteschema

    Critical Accessibility Issues Found


    🚨 SEVERE ACCESSIBILITY CONCERNS

    Toilet Rooms (Toiletruimte) - MAJOR ISSUES

    These rooms are critically undersized for wheelchair access:

    Room NumberRoom NameAreaAccessibility Status
    d.0.04aToilet D.1.14 m²INACCESSIBLE
    d.0.05aToilet H.1.14 m²INACCESSIBLE
    c.0.04aToilet D.1.14 m²INACCESSIBLE
    c.0.05aToilet H.1.14 m²INACCESSIBLE
    d.1.04aToilet D.1.17 m²INACCESSIBLE
    d.1.05aToilet H.1.19 m²INACCESSIBLE
    c.1.04aToilet D.1.17 m²INACCESSIBLE
    c.1.05aToilet H.1.19 m²INACCESSIBLE

    Standard Requirement: Accessible toilet rooms need minimum 2.2-2.5 m² for basic wheelchair access, 4-6 m² for full accessibility with turning space.

    MIVA Rooms - POTENTIALLY ACCESSIBLE

    Room NumberRoom NameAreaAccessibility Status
    d.0.06MIVA3.86 m²⚠️ MARGINAL - Needs verification
    c.0.06MIVA3.86 m²⚠️ MARGINAL - Needs verification

    Note: MIVA rooms appear to be designed for mobility access but should be verified for proper layout and fixture placement.


    ⚠️ CIRCULATION CONCERNS

    Entrance Areas (Verkeersruimte) - LIMITED ACCESS

    Room NumberRoom NameAreaAccessibility Status
    d.0.04Voorportaal D.1.67 m²TOO NARROW
    d.0.05Voorportaal H.1.67 m²TOO NARROW
    c.0.04Voorportaal D.1.67 m²TOO NARROW
    c.0.05Voorportaal H.1.67 m²TOO NARROW
    d.1.04Voorportaal D.1.72 m²TOO NARROW
    c.1.04Voorportaal D.1.72 m²TOO NARROW

    General Circulation - MARGINAL

    Room NumberRoom NameAreaAccessibility Status
    d.0.02aVoorportaal5.38 m²⚠️ REQUIRES VERIFICATION
    c.0.02aVoorportaal5.38 m²⚠️ REQUIRES VERIFICATION
    d.1.05Voorportaal H.5.83 m²⚠️ REQUIRES VERIFICATION
    c.1.05Voorportaal H.5.83 m²⚠️ REQUIRES VERIFICATION

    Standard Requirement: Corridors need minimum 1.5m width; entrance areas should allow 1.5m diameter turning circle.


    ✅ ACCESSIBLE SPACES

    Large Functional Spaces

    Room NumberRoom NameAreaAccessibility Status
    d.0.02Kantoor227.85 m²ACCESSIBLE
    c.0.02Kantoor228.04 m²ACCESSIBLE
    d.1.02Kantoor237.28 m²ACCESSIBLE
    c.1.02Kantoor237.63 m²ACCESSIBLE
    c.0.01Unit C11,797.69 m²ACCESSIBLE
    d.0.01Unit D14,862.72 m²ACCESSIBLE
    d.1.01Mezaninne1,110.37 m²ACCESSIBLE
    c.1.01Mezaninne828.11 m²ACCESSIBLE

    Utility/Service Spaces

    Room NumberRoom NameAreaAccessibility Status
    e.0.01Pompkamer35.34 m²ACCESSIBLE
    c.0.03Opslag4.86 m²⚠️ LIMITED ACCESS
    d.0.03Opslag4.79 m²⚠️ LIMITED ACCESS
    c.1.03Technische ruimte4.86 m²⚠️ LIMITED ACCESS
    d.1.03Technische ruimte4.86 m²⚠️ LIMITED ACCESS

    🔍 SUMMARY & RECOMMENDATIONS

    Immediate Action Required

    1. All standard toilet rooms are INACCESSIBLE - require complete redesign
    2. Entrance areas are too narrow - need layout revision
    3. 8 rooms have severe accessibility barriers

    Rooms Requiring Design Verification

    • MIVA rooms: Verify fixture placement and turning radius
    • Circulation spaces: Check corridor widths and door clearances
    • Storage rooms: Consider if wheelchair access is required

    Compliance Requirements

    • Toilet rooms: Minimum 2.2 m² for basic access, 4-6 m² for full accessibility
    • Door openings: Minimum 0.8m clear width
    • Corridors: Minimum 1.5m width
    • Turning space: 1.5m diameter circle minimum

    Building Code Compliance Status

    SIGNIFICANT NON-COMPLIANCE with accessibility standards for essential facilities (toilets and circulation)


    Analysis completed: June 12, 2025
    Total rooms analyzed: 33
    Rooms with accessibility concerns: 16

    Made with